TROUBLESHOOTING & REPAIR

F-43

F-43

INVERTEC® STT® & STT® II

POWER BOARD TEST (continued)

FIGURE F.15 – POWER PC BOARD TEST POINTS

POWER BOARD

J6

J7

J14

L8033

501

504

302

275

211A

305

311

313

309

310

301

212A

4. Secure and insulate the front panel assembly

for POWER ON testing.

ELECTRIC SHOCK can
kill.

• With input power ON,

there are high voltages
inside the machine. Do
not reach into the machine
or touch any internal part.

5. Apply the correct input power and turn ON the

machine.

6. Carefully test for 18VAC input from the T1

Auxiliary Transformer between plug J7 pin 5
(lead#501) and plug J7 pin 6 (lead #504) at
the power PC board. See Figure F. 15.

NOTE: If the 18VAC is NOT present, perform

the T1 Auxiliary Transformer Test.
Also check associated wiring. See the
Wiring Diagram.