Troubleshooting & repair, Igbt module removal and replacement (continued), Warning – Lincoln Electric INVERTEC SVM129-B User Manual

Page 92

Advertising
background image

TROUBLESHOOTING & REPAIR

F-54

F-54

INVERTEC® STT® & STT® II

IGBT MODULE REMOVAL

AND REPLACEMENT (continued)

FIGURE F.23 – OUTPUT CHOKE LEAD DISCONNECTION

LOWER

TRAY

AREA

OUTPUT CHOKE/
IGBT MODULE
SPLICED CONNECTION

PROCEDURE

1. Turn off the INVERTEC® STT® & STT® II

and disconnect main AC input power to the
machine.

2. Using the 5/16" nut driver, remove the case

wraparound cover.

3. Perform

the

Input

Filter

Capacitor

Discharge Procedure. See the Maintenance
section.

ELECTRIC SHOCK can
kill.

• Before continuing with the

test procedure, perform
the capacitor discharge
procedure to avoid electric
shock.

4. Locate the lead connection splice from the

output choke to the IGBT module. Remove
the insulating sleeve. Using the 7/16" wrench
disconnect the lead splice. Thread the lower
lead down into the lower tray assembly area.
See Figure F.23.

WARNING