TROUBLESHOOTING & REPAIR

F-17

F-17

INVERTEC® STT® & STT® II

ELECTRIC SHOCK can
kill.

• With input power ON,

there are high voltages
inside the machine. Do
not

reach

into

the

machine or touch any
internal part.

15. Apply the correct input power and carefully

test for the correct primary voltages at plug
J21. See Table F.1.

16. If the correct AC input voltages are applied

to the primary windings and any or all of the
secondary voltages are missing or not cor-
rect, the T1 auxiliary transformer may be
faulty.

17. After all tests are complete, reconnect plugs

J30 and J31.

18. Install the case wraparound cover.