TROUBLESHOOTING & REPAIR

F-14

F-14

INVERTEC® STT® & STT® II

T1 AUXILIARY
TRANSFORMER

PLUG

J31

PLUG

J30

FIGURE F.1 – T1 AUXILIARY TRANSFORMER AND J30/J31 LOCATION

T1 AUXILIARY TRANSFORMER TEST (continued)

TEST PROCEDURE

1. Turn off INVERTEC® STT® & STT® II and

disconnect main AC input power to the
machine.

2. Using the 5/16" nut driver, remove the case

wraparound cover.

3. Perform the Input Filter Capacitor

Discharge

Procedure.

See

the

Maintenance section.

ELECTRIC SHOCK can
kill.

• Before continuing with

the test procedure, per-
form the capacitor dis-
charge

procedure

to

avoid electric shock.

4. Locate the T1 auxiliary transformer and sec-

ondary lead molex plugs (J30 and J31) on
the left side, just in front of the main trans-
former assembly. Check for broken or loose
wires. See Figure F.1.