A-4

INSTALLATION

LN-8

A-4

LN-8S AND LN-8SE (AND CONVERTED
LN-8N AND LN-8NE)

1. Use either a constant voltage or constant current

type power source as required for the application.
Ensure the power source is properly set for
constant voltage or constant current welding, as
appropriate, per the instructions in the power
source operating manual.

2. Set the LN-8 wire feeder for a constant voltage or

constant current power source as appropriate per
the following:

a. There are two nameplates on the front of the

wire feeder, one mounted on top of the other.
Be sure the ‘Constant Current Power Source’
nameplate is on top when using a constant
current power source. When connected to a
constant voltage power source, be sure the
‘Constant Voltage Power Source’ nameplate is
on top.

b. Turn the power to the wire feeder off. Open the

door to the control section and switch the
power source selection switch to constant
current ‘CC’ or constant voltage ‘CV’ as
appropriate. See Figure A.1.

3. Connect the LN-8 input cable to the power source

exactly as specified in the wire connection
diagrams in

Table A.2

. Include any jumpers on

the terminal strips as shown in the connection
diagrams.

4. Connect a work lead of sufficient size and length,

per

Table A.1

, between the appropriate output

terminal on the power source and the work.
Ensure the connection to the work makes tight
metal-to-metal contact.

FIGURE A.1 – POWER SOURCE SELECTION

SWITCH

POWER SOURCE

SELECTION SWITCH

VARIABLE

VOLTAGE

PC BOARD

VARIABLE

VOLTAGE

PC BOARD

Advertising