TROUBLESHOOTING AND REPAIR

F-18

TEST PROCEDURE

1. Remove input power to the LN-8.

2. Using the 5/16 in. nutdriver,

remove the screws from the left
side cover assembly.

3. Lift the left side cover.

4. Locate the 1CR relay. Slide the

retaining clip off the relay and
carefully remove the relay from the
relay board. See Figure F.4.

Note: The Molex plug located on the
relay board may have to be removed to
gain access to the 1CR relay.

5. Connect the 24VDC supply to ter-

minals A- and B+ on the 1CR
relay. Do not energize the power
supply at this time.

6. Connect the ohmmeter across the

first set of terminals shown in
Table F.2.

LN-8

1CR RELAY TEST

(continued)

FIGURE F.4 – 1CR RELAY TEST POINTS

1

2

3

4

5

6

7

8

9

A

B

NORMALLY CLOSED

NORMALLY OPEN

COMMON

-

+

24VDC

MOLEX

PLUG

RELAY

BOARD

RETAINING

CLIP

1CR RELAY