E-4

THEORY OF OPERATION

E-4

VARIABLE VOLTAGE
BOARD, METER SHUNT,
WIRE SPEED AND
REMOTE OUTPUT
CONTROLS

The optional variable voltage board
enables the LN-8 to be used with a con-
stant current power source. The vari-
able voltage board monitors the arc
voltage via leads #21 and #567 and
modifies the wire feed speed according
to arc voltage variations and require-
ments.

The wire speed control dictates to the
control board the directives of the

operator. The control board adjusts the
armature voltage applied to the wire
feed motor to change the motor speed.

The remote output control permits
power source control from the LN-8
unit. The remote control is coupled to
the welding power source via leads #75,
#76, and #77 through the input
receptacle.

The electrode meter shunt, which is
connected to and also in series with the
gun connector block, senses the weld-
ing current and arc voltage. This infor-
mation is used by the variable voltage
board and also the optional meter kit.

FIGURE E.3 – VARIABLE VOLTAGE BOARD, METER SHUNT, WIRE SPEED,

AND REMOTE OUTPUT CONTROLS

LN-8

REMOTE

OUTPUT

CONTROL

ELECTRODE

METER
SHUNT

WIRE
FEED

MOTOR

CIRCUIT

BREAKER

INPUT

RECEPTACLE

VARIABLE VOLTAGE

BOARD

CONTROL

BOARD

WIRE FEED

SPEED CONTROL

THERMAL

CIRCUIT

BREAKER

RELAY

BOARD

GLP

REED

SWITCH

TRIGGER

TRANS.

WIRE

FEED

SWITCH

INTERLOCK

SWITCH

FUSE

GUN

CABLE

RECEPTACLE

FIELD

ARMATURE

#3

2

A

OPTIONAL

BURNBACK

BOARD

CONTROL

#2

&

#4

C

O

N

T

A

C

T

O

R

#531

#31

2 OHMS

#32

#32A

#75
#76
#77

#21

#567

NOTE: Unshaded areas of block logic diagrams are the subject of discussion.