TROUBLESHOOTING AND REPAIR

F-19

7. Measure the resistance across the

contacts. A resistance of less than
one ohm indicates that the con-
tacts are closed. An infinite resis-
tance indicates that the contacts
are open. Energize the 24VDC
power supply and measure the
resistance again. Compare to the
conditions given in Table F.2. If the
readings do not match the table,
the relay is faulty and should be
replaced.

8. Repeat the above procedure for all

of the contacts.

9. Re-install relay into the relay

board.

10. Install the screws that secure the

left side cover assembly.

1CR RELAY TEST

(continued)

TABLE F.2 – RELAY TEST TERMINAL CONNECTIONS

LN-8

Terminals

Terminals

A&B

A&B

Terminals

Energized

De-energized

7-1

Open

Closed

7-4

Closed

Open

8-2

Open

Closed

8-5

Closed

Open

9-3

Open

Closed

9-6

Closed

Open