To ln-8 for opposite polarity operation, A-13, Installation – Lincoln Electric LN-8 SVM132-A User Manual

Page 19

Advertising
background image

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

A-13

INSTALLATION

A-13

LN-8

GND

77
76
75

32

31

2

4

A
B
C

4
2

GND

32

31

21

DUAL PROCESS
CONTACTOR

4
2

32

31

75
76
77

A

A

4
2

32

31

75
76
77

B

B

A
B
C

4
2

GND

32

31

21

81

80

ELECTRIC

SHOCK

CAN KILL

TURN OFF INPUT POWER
TO THE WELDING POWER
SOURCE USING THE
DISCONNECT SWITCH
BEFORE WORKING
ON THIS EQUIPMENT.

WARNING

4

21

32

DC-400

TO WORK

TO NEGATIVE OUTPUT

STUD ON POWER

SOURCE

TO POSITIVE OUTPUT

STUD ON POWER

SOURCE

2

31

75

76

77

WELDER

CONTROL

CABLE

N.A.

N.C.

N.F.

21A

21B

N.B.B.

WELDING LEAD STUD ON
BACK OF CONTACTOR KIT

N.E.

N.A.

N.D.

ELECTRODE

CABLES

WIRE FEEDER

CONTROL

CABLE

WIRE FEEDER

CONTROL

CABLE

TO "A" WIRE FEEDER

ELECTRODE NEGATIVE

TO "B" WIRE FEEDER

ELECTRODE POSITIVE

N.B.

N.B.

N.A.

FOR 50 HZ OPERATION, DISCONNECT BOTH BROWN LEADS FROM TERMINAL 31B AND TAPE UP EACH LEAD. UNTAPE BOTH RED LEADS

AND CONNECT TO 31B.

N.A.A. CONNECT THE LN-8 CONTROL CABLE GROUND LEAD TO THE FRAME MARKED NEAR THE POWER SOURCE TERMINAL STRIP OR

TO AN UNPAINTED FRAME SCREW. THE POWER SOURCE MUST BE PROPERLY GROUNDED.

N.B.B. EXTEND LEAD #21A AND #21B USING #14 OR LARGER INSULATED WIRE PHYSICALLY SUITABLE FOR THE INSTALLATION. AN S16586-[]

REMOTE VOLTAGE SENSING WORK LEAD IS AVAILABLE FOR THIS PURPOSE. CONNECT IT DIRECTLY TO THE WORK PIECE, KEEPING IT
ELECTRICALLY SEPARATE FROM THE WELDING WORK LEAD CIRCUIT AND CONNECTION. FOR CONVENIENCE, THESE EXTENDED #21A AND
#21B LEADS SHOULD BE TAPED TO THE WELDING WORK LEAD. EACH LEAD MUST BE CONNECTED DIRECTLY TO THE WORK AND LEADS
MUST NOT BE CONNECTED TOGETHER.

N.A. WELDING CABLES MUST BE OF PROPER CAPACITY FOR THE CURRENT AND DUTY CYCLE OF IMMEDIATE AND FUTURE APPLICATIONS.
N.B. BOLT AND TAPE CONNECTIONS.
N.C. TAPE UP SEPARATELY.
N.D. PUT TRANSFER SWITCH IN "OPPOSITE POLARITY ON FEEDERS" POSITION.
N.E. MODE SWITCHES ON CONTACTOR KIT ARE NOT FUNCTIONAL WHEN USED WITH THE POWER SOURCE.
N.F. TO MAKE "A" FEEDER POSITIVE POLARITY AND "B" FEEDER NEGATIVE POLARITY, REVERSE ELECTRODE CABLES CONNECTED TO

POWER SOURCE OUTPUT STUDS.

N.A.A.

N.B.B.

N.A.

FIGURE A.9 – K318 DUAL PROCESS CONTACTOR KIT DC-400, CV-400 AND CVI-500 CONNECTION TO

LN-8 FOR OPPOSITE POLARITY OPERATION

CLEVELAND, OHIO U.S.A.