Troubleshooting and repair – Lincoln Electric LN-8 SVM132-A User Manual

Page 61

Advertising
background image

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-11

TROUBLESHOOTING AND REPAIR

F-11

FIGURE F.1 – LN-8 ELECTRICAL SEQUENCE OF OPERATION (continued)

LN-8

DE-ENERGIZES

2 CR

REED SWITCH

OPENS INTERLOCK

ON 1 CR (NOTE 2)

OPENS 531-7

DE-ENERGIZES 1 CR

OPENS 683-32A CIRCUIT

CLOSES 682-683

REVERSES

MOTOR FIELD

WELDING

ELECTRODE IS

COLD TO WORK

RELEASE

GUN TRIGGER

OPENS 2-8 (NOTE 1)

OPENS 2-4 CIRCUIT

DE-ENERGIZES

POWER SOURCE

CONTACTOR

BREAK

WELDING ARC

DE-ENERGIZES

POWER SOURCE

PILOT RELAY

DISCONNECTS MOTOR ARMATURE

AND CONTROL CIRCUIT FROM

INPUT AC LINE - (DE-ENERGIZES

AUX. EQUIPMENT IF CONNECTED)

3CR (NOTE 3)

REED SWITCH

MOMENTARILY

CLOSES

DYNAMIC BRAKE

CURRENT FLOWS

THROUGH FREE

WHEELING DIODE (D-7 ON

CONTROL BOARD)

DISCHARGES SLOW

ACCELERATION

CAPACITOR (C3 ON

CONTROL BOARD)

MOTOR STOPS

RESETS SLOW

ACCELERATION

CIRCUIT

UNIT READY

FOR NEXT WELD

NOTE 1: When interlock is open.
NOTE 2: When interlock is closed.
NOTE 3: 3 CR is not used on units with code no. 7926 and up.

Advertising