Troubleshooting and repair, Trigger transformer test – Lincoln Electric LN-8 SVM132-A User Manual

Page 63

Advertising
background image

F-13

TROUBLESHOOTING AND REPAIR

F-13

TEST PROCEDURE

1. Remove input power to the LN-8.

2. Using the 5/16 in. nutdriver,

remove the screws holding the left
side cover assembly.

3. Disconnect the Molex plug from

the under-side of the relay board.
See Figure F.2.

4. Apply power (115VAC) to the

black primary transformer leads,
pins 2 and 3.

5. Using the voltmeter, check for

approximately 24VAC at the red
secondary leads, pins 1 and 4.

6. If 115VAC is applied to the black

primary leads (2 and 3) and the
secondary voltage (red leads 1
and 4) is missing or low, the trig-
ger transformer may be faulty.
Replace.

7. Reconnect the Molex plug to the

underside of the relay board.

8. Install the screws that secure the

left side cover assembly.

TRIGGER TRANSFORMER TEST

(continued)

FIGURE F.2 – TRIGGER TRANSFORMER TEST POINTS

LN-8

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

6 5 4

3 2 1

BLACK

BLACK

RED

RELAY

BOARD

Advertising