A-8

INSTALLATION

A-8

LN-8

ELECTRIC

SHOCK

CAN KILL

TURN OFF INPUT POWER
TO THE WELDING POWER
SOURCE USING THE
DISCONNECT SWITCH
BEFORE WORKING
ON THIS EQUIPMENT.

WARNING

TO WORK

TO LN-8 INPUT
CABLE PLUG

ELECTRODE CABLE TO
WIRE FEED UNIT

21

2

31

32

GND

A

B

C

4

AUTO

EQUIP.

STICK

WORK

TAPE

UP

67

21

2

31

32

C4

76

77

75

N.A.

CONTROL CABLE

N.B.

CONNECT THE LN-8 CONTROL CABLE GROUND LEAD TO THE FRAME TERMINAL MARKED NEAR THE POWER SOURCE TERMINAL STRIP

OR TO AN UNPAINTED FRAME SCREW. THE POWER SOURCE MUST BE PROPERLY GROUNDED.

N.A. EXTEND LEAD #21 USING #14 OR LARGER INSULATED WIRE PHYSICALLY SUITABLE FOR THE INSTALLATION. AN S16586-[ ]

REMOTE VOLTAGE SENSING WORK LEAD IS AVAILABLE FOR THIS PURPOSE. CONNECT IT DIRECTLY TO THE WORK PIECE, KEEPING IT
ELECTRICALLY SEPARATE FROM THE WELDING WORK LEAD CIRCUIT AND CONNECTION. FOR CONVENIENCE, THIS EXTENDED LEAD #21
SHOULD BE TAPED TO THE WELDING WORK LEAD. (THIS EXTENDED #21 LEAD CONNECTION REPLACES THE NEED TO EMPLOY THE
REMOTE WORK LEAD ACCESSORY ON LN-8 METER KITS WHICH HAVE A DIRECT WORK LEAD JACK).

N.B. IF USING AN OLDER LN-8 CONTROL CABLE (PRIOR TO USE OF A, B, AND C MARKING): CONNECT LEAD #76 TO #76 ON TERMINAL

STRIP, CONNECT LEAD #77 TO #75 ON THE TERMINAL STRIP, AND TAPE UP LEAD #75.

1

REMOVE SAM PORTABLE FIELD CONTROL AND

CONNECT LEADS B AND C FROM LN-8 CONTROL CABLE.

DO NOT CONNECT LEAD A. LEAD MUST BE TAPED UP.

POWER
SOURCE

TAPE UP

BOLTED

CONNECTION

FIGURE A.4 – CONNECTION OF LN-8 TO A SAM MOTOR-GENERATOR OR ENGINE DRIVEN WELDER