F-29

TROUBLESHOOTING AND REPAIR

F-29

REPAIR PROCEDURE

1. Using the 5/16 in. nutdriver,

remove the screws from the left
side cover assembly.

2. Using the 3/32 in. wrench and jew-

elers’ flat blade screwdriver,
remove the ground lead protector
switch from the switch mount.
Refer to Figure F.8.

3. Remove insulation and unsolder

the two leads from the ground lead
protector switch.

4. Solder the two leads onto the

new switch and reinsulate the
connections.

5. Place the switch onto the switch

mount and install the screws, flat
washers, lockwashers and nuts
that secure the switch into place.

6. Install the screws that secure the

left side cover assembly.

LN-8

GROUND LEAD PROTECTOR PUSH BUTTON

SWITCH REPLACEMENT

(continued)