LaserSpeed 8000-3 Instruction Handbook

RS-232/RS-422 Communication

Part No. 93463 / Drawing No. 0921-01561

Page 138 of 221

Revision A (Sep 2007)

Example:

If using two external Material Present detectors and the detectors are mounted 4 feet apart,
you would set the Length Reset Value to 4 feet to automatically add 4 feet to each
measurement.

Assuming that the gauge's measurement units are in feet, to set the value to 4.000 ft, you
would send the command:

$R4000<CR>

U

Measurement Units

U<CR>

Read

Response

Format:

<N>

U<N><CR>

Set

<N>

is an integer specifying the Measurement Units. When changing the measurement

units, be sure to update the Pulse/Length settings (L and P) if you want to maintain the same
pulse output frequency for a given speed.

Value Units

0 m/s

1 ft/s

2 ft/min

3 m/min

4 in/min

5 mm/min

6 mm/s

7 yards/min

8 yards/s

Note: Changing this setting will cause a reset, will reset the indicated length, and will cause
the pulse outputs to be momentarily interrupted. Do not change this setting during normal
operation.