Laser beta lasermike LS8000-3 User Manual

Page 51

Advertising
background image

LaserSpeed 8000-3 Instruction Handbook

Interfacing with the LS8000-3

Part No. 93463 / Drawing No. 0921-01561

Page 51 of 221

Revision A (Sep 2007)

Measurement Direction Input (Pin 14)

This is an optically isolated input that can be used to externally control the
Measurement Direction feature of the LS8000-3. The input requires a voltage
high (5 to 24V) to activate. The input level should be the same as the voltage
connected to the User V

IN

input (Pin 20) or 5V if there is nothing connected to

the User V

IN

input.

Optically Isolated Input Schematic

There are two ways to reverse the direction of the LS8000-3's measurements:

1. Modify the Direction Inversion setting with LaserTrak (or using the "A"

serial command)

2. Connect 5-24V to the Measurement Direction Input

Changing the Direction Inversion setting with LaserTrak to invert the direction has
the same effect as changing the state of this input.

Note: If the Direction Inversion setting is set to "Reverse +/- Directions" and

the Measurement Direction Input is high, they will cancel each other
out and the LS8000-3 will operate in the default manner.

Direction

Inversion Setting Measurement Direction Input LS8000-3 Direction

Normal

Low (Disconnected or 0v)

Normal

Normal High

(5-24V) Reversed

Reversed

Low (Disconnected or 0v)

Reversed

Reversed High

(5-24V) Normal