Laser beta lasermike LS8000-3 User Manual

Page 54

Advertising
background image

LaserSpeed 8000-3 Instruction Handbook

Interfacing with the LS8000-3

Part No. 93463 / Drawing No. 0921-01561

Page 54 of 221

Revision A (Sep 2007)

Length Reset Input Circuit

The Length Reset Input Action configuration setting affects how this input
resets the length. The input can be configured to reset the length on level and
edges. See the Length Reset Input Action command description in the

Configuration Settings

section for details.

User V

IN

(Pin 20)

Voltage input for Isolated Pulse Outputs, and the Index Pulse Output.
Connecting a voltage from 5-28VDC to this input allows you to control the
pulse amplitude of the LS8000-3 Scaleable Pulse Outputs (Pins 15, 5, 6, 8),
and the Index Pulse Output (Pins 22 and 23.) The voltage supplied will be the
voltage level of the pulse outputs supplied by the LS8000-3. If a voltage is not
supplied, the pulse outputs will be approximately 4.5V.

Pulse Output

Internal Isolated +5V

Signal Ground
(Pins 11, 19, 21)

User V (Pin 20)

IN

Pulse True
Pulse False

GND

User V

IN

GND

User V

IN

User V

IN

Schematic