LaserSpeed 8000-3 Instruction Handbook

Appendix E: Troubleshooting Guide

Part No. 93463 / Drawing No. 0921-01561

Page 210 of 221

Revision A (Sep 2007)

























Environmental Conditions
(i.e. roll coolant, or coolant
mist, spray and fume) are
adversely affecting the
measurement.


verify that the gauge is at the correct
standoff distance.

2. Verify that the gauge is mounted in

the correct orientation.

3. Check the E setting – must be set to

31 to enable all signal ranges.

4. Check Minimum and Maximum

Velocities, and set to large negative
and positive values respectively.


Result C: The gauge emits no (zero)
laser beams.
1. Make sure the laser interlock is

closed, and that the LASER ON LED
is illuminated.

2. Make sure the shutter interlock is

closed, and that LaserTrak indicates
that the beam shutter is open.

3. Check the gauge temperature, and

connect coolant lines if required.

4. "Ring-out" the cable to make sure it

isn't damaged.


Result D: The gauge emits only one
laser beam.
1. Contact Beta LaserMike for

assistance.




1. Inspect the environmental conditions

at the measurement area.

2. Check the operating conditions of

the compressed air utilities.

3. If using a beam path air purge, check

the clean make-up air duct for any
damage (holes and tears) that may
be drawing in contaminated make-up
air from the mill environment.

4. Install proper beam path air purge

and/or air wiping (air knife) system to
keep optical beam path and
measured surface clear and clean.

Valid LED is not illuminated

Incorrect sensor orientation

Rotate the sensor so that it matches the
diagram in the

Aligning the Gauge

section.

"Valid Data" LED is flickering ON
and OFF

Dirty quick change window

1. Check the quick change window for

contamination.

2. Clean or exchange quick change

Advertising