Laser beta lasermike LS8000-3 User Manual

Page 44

Advertising
background image

LaserSpeed 8000-3 Instruction Handbook

Interfacing with the LS8000-3

Part No. 93463 / Drawing No. 0921-01561

Page 44 of 221

Revision A (Sep 2007)

Material Present

Transition Effect

Material Present

Input Mode

High (5-24V)

Low (0V)

Low High High Low

0 (Internal)

N/A

N/A

No Effect

No Effect

1

(External Active

Low)

No

("Material Not

Present")

Yes

("Material Is

Present")

Ends Current

Measurement

Starts New

Measurement

2

(External Active

High)

Yes

("Material Is

Present")

No

("Material Not

Present")

Starts New

Measurement

Ends Current

Measurement

Note: If Material Present functionality isn't required, and you want Material

Present to always be on, then set the LS8000-3's Material Present
Input Mode to External Active Low, and leave the Material Present
Input disconnected.