Index Pulse Output Function

#<CR>

Read

Response

Format:

<N>

#<N><CR> Set

<N> is an integer specifying the function of the Index Pulse output. This command
reconfigures the Index Pulse Output to be a status output.

Value Index Pulse Output Function

0

(Default) Index (OPR) Pulse Output

1

Material Present Output

2 Valid

Measurement

Output

3

QF Pulse Output

4 QF

Warning

Output

5 Shutter

Open

6 Laser

On

7 System

Ready

8

Thermostat Output (on @ 40C, off @ 35C)

9

Light Stack Green

10

Length Threshold A

Material Present Output
This output reflects the Material Present status. It is the same as the Material Present bit in
the status word of the serial output data.
Voltage High: Material is present
Voltage Low: Material is not present

Valid Measurement Output
This output indicates if the gauge is making valid measurements. The output is the same as
the Valid LED on the gauge.
Voltage High:
Valid Measurements are being made
Voltage Low:
No measurements are being made

QF Pulse Output
This output is a frequency output that indicates the current Quality Factor. A frequency of
100Hz indicates a QF of 0, and a frequency of 1kHz indicates a QF of 15. The frequency of
the output increases by 60Hz with each increase of 1 in the QF (100, 160, 220, 280, 340, …,
940, 1000)