Domino a series – Laser beta lasermike LS8000-3 User Manual

Page 84

Advertising
background image

LaserSpeed 8000-3 Instruction Handbook

Interfacing with the LS8000-3

Part No. 93463 / Drawing No. 0921-01561

Page 84 of 221

Revision A (Sep 2007)

Domino A Series

Pinout

Signal

Domino A200

LaserSpeed

Signal A

2

15

Print Go

3

22

Signal Ground

1

11

User Voltage

4

20


Notes:

Configure the LaserSpeed for the appropriate pulse per unit length.

The index pulse should be set to trigger at the appropriate rate (every 2
feet, every 1 meter, etc), and with a 20 ms pulse width.

On the Domino A-Series printer, the Strobe Divide should be set to 1.
There are two ports that are in parallel so it doesn’t matter which one is

used. The other port would not be used. The printer should be set for
EXTERNAL print and the REPEAT PRINTING should be turned off.

Advertising