H high speed pulse output configuration, Lhigh speed pulse rate – Laser beta lasermike LS8000-3 User Manual

Page 144

Advertising
background image

LaserSpeed 8000-3 Instruction Handbook

RS-232/RS-422 Communication

Part No. 93463 / Drawing No. 0921-01561

Page 144 of 221

Revision A (Sep 2007)

The output will clear when the length reaches 200ft, and the Index Pulse triggers. See the

Index Pulse & Length Thresholds

section for timing details.

$H

High Speed Pulse Output Configuration

$H<CR>

Read

Response

Format:

<N>

$H<N><CR>

Set

<N>

is an integer that specifies the function of the High Speed Pulse Output. The various

outputs were described previously in the Index Pulse Output Function description.

Pulse Output Function

Value

Phase A

Phase B

0

Default (High Speed Pulse Outputs)

1

System Ready

Material Present

2 System

Ready Valid

3

System Ready

QF Pulse Output

4

System Ready

QF Warning Output

5

System Ready

Shutter Open

6

System Ready

Laser On

7

System Ready

Thermostat Output

8 Valid

Thermostat

Output

9

Pulse Phase A

Sync Output

Note: Some of the above outputs were previously described under the Index Pulse Output
Function
setting.

Sync Output

Gauge-Gauge Synchronization Output that can be connected between multiple gauges in
order to synchronize measurements. See the

Gauge-Gauge Synchronization

section for

details.

L

High Speed Pulse Rate

L<CR>

Read

Response

Format:

<N>

L<N><CR>

Set

Advertising