Laser beta lasermike LS8000-3 User Manual

Page 74

Advertising
background image

LaserSpeed 8000-3 Instruction Handbook

Interfacing with the LS8000-3

Part No. 93463 / Drawing No. 0921-01561

Page 74 of 221

Revision A (Sep 2007)

Index Pulse & Length Thresholds

The Index Pulse and Length Thresholds can be used to control a cutter and
provide pre-cut queues to the process control system so, for example, the line
can be slowed prior to a cut. The Index Pulse is configured to trigger at a
specified length interval, and the Length Thresholds can be configured to
trigger at preset lengths before the Index Pulse triggers. The Length
Threshold outputs remain high until the Index Pulse triggers and resets. The
index pulse automatically resets the Length Threshold outputs—no external
wiring is required.

Another way to reset these outputs is to set the Index Pulse Setting to a high
value and reset the threshold outputs by asserting the Length Reset Input.

The Length Thresholds are available as an alternate output function of the
User Scaleable Pulse Output.

Example:

Setting

Value

Index Pulse Setting

100 m

Index Pulse Length

100 ms

Length Threshold A

90 m

Length Threshold B

80 m