Installation, Rated output, Output – Lincoln Electric IDEALARC R3R-500 User Manual
Page 10: Physical dimensions
Advertising
INSTALLATION
A-4
A-4
IDEALARC R3R
TECHNICAL SPECIFICATIONS - IDEALARC R3R-500
INPUT - THREE PHASE ONLY
Standard Voltage
Input Current @ Rated Output
230V
88A
460V
44A
RATED OUTPUT
Duty Cycle
Amps
Volts at Rated Amps
100%
600
44
60%
500
40
35%
375
35
OUTPUT
Current Range
Maximum Open Circuit Voltage
75 to 625 Amps
67 VDC
RECOMMENDED INPUT WIRE AND FUSE SIZES AT 60% DUTY CYCLE
Input Wire Size
Ground Wire Size
Input Voltage /
Fuse
Input Ampere
Type 75°C
Type 75°C
Frequency
(Super Lag)
Rating on
Copper Wire in
Copper Ground
or Breaker Size
Nameplate
Conduit
Wire in Conduit
Volts/Hz
AWG (IEC) Sizes
AWG (IEC) Sizes
230/60
150
88
4 (25 mm
2
)
6 (16 mm
2
)
460/60
70
44
8 (10 mm
2
)
8 (10 mm
2
)
PHYSICAL DIMENSIONS
Height
Width
Depth
Weight
27.50 in.
22.25 in.
33.10 in.
446 lbs.
(700 mm)
(565 mm)
(840 mm)
(202 kg)
Advertising
This manual is related to the following products: