RETEST AFTER REPAIR (R3R 300)

Retest a machine:

• If it is rejected under test for any reason that requires you to remove any mechanical part which could affect the

machine’s electrical characteristics. OR

• If you repair or replace any electrical components.

INPUT IDLE AMPS AND WATTS

Input Volts/Phase/Hertz

Maximum Idle Amps

Maximum Idle KW

200/3/60

8.1

0.92

208/3/60

7.8

0.92

230/3/60

7.0

0.92

400/3/60

4.0

0.92

440/3/60

3.7

0.92

460/3/60

3.5

0.92

480/3/60

3.4

0.92

575/3/60

2.8

0.92

200/3/50

14.4

1.0

220/3/50

13.0

1.0

380/3/50

7.5

1.0

400/3/50

7.2

1.0

415/3/50

6.9

1.0

425/3/50

6.7

1.0

440/3/50

6.5

1.0

500/3/50

5.7

1.0

550/3/50

5.2

1.0

OPEN CIRCUIT VOLTAGES

Test Points

Input Hertz

Open Circuit Volts

Welding Output Terminals

60

63/68VDC

Welding Output Terminals

50

61/65VDC

WELDING OUTPUT LOAD TEST

Output Control Settings

Amps

Volts

Current Control at

40

20VDC (Maximum)

Minimum

Current Control at

375

39 to 45 VDC

Maximum