Troubleshooting & repair, Warning – Lincoln Electric IDEALARC R3R-500 User Manual

Page 74

Advertising
background image

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

TROUBLESHOOTING & REPAIR

F-40

F-40

IDEALARC R3R

INPUT CONTACTOR (CR1) CLEANING/REPLACEMENT (continued)

FIGURE F.25 – INPUT CONTACTOR CLEANING AND REMOVAL

CLEANING PROCEDURE

1.

Remove the main input supply power to the
machine.

2.

Locate and get access to the input contac-
tor (CR1) in the input box. See Figure F.25.

3.

Remove the input contactor cover plate
using a phillips head screwdriver.

Do not apply input power to
the machine with the input
contactor cover plate re-
moved.

4.

Blow out any dirt or dust in or around the
contacts with a low pressure air stream.

5.

Inspect the contacts for signs of excessive
wear, pitting, or contacts fused (stuck)
together.

a.

If any of these conditions are present,
replace the input contactor assembly.

6.

Replace the input contactor cover plate.

CONTACTOR REPLACEMENT
PROCEDURE

1. Disconnect main input supply power to the

machine.

2. Locate and get access to the input contac-

tor (CR1) in the input box. See Figure F.25.

3. Disconnect the main input supply power

leads L1, L2, and L3 to the input contactor.

Remove the control transformer primary
leads H1, H2 or H3 (dependent on input volt-
age) from L1 and L3 terminals on the input
side of the contactor.

4. Disconnect the output leads T1, T2, and T3

from the input contactor.

5. Identify and label the leads connected to the

input contactor coil. See the Wiring
Diagram.

6. Disconnect the leads from the input contac-

tor coil (leads X1, #232 and #233). See the
Wiring Diagram.

7. Remove the three self-tapping mounting

screws using a 5/16” socket wrench. See
Figure F.25.

8. Remove the input contactor.

9. Insert the replacement input contactor and

install it following the procedures in reverse
order.

NOTE: Be sure to reconnect all leads cor-
rectly.

WARNING

1. INPUT SUPPLY LINE
2. INPUT CONTACTOR CR1
3. RECONNECT PANEL

Advertising
This manual is related to the following products: