Installation, Rated output, Output – Lincoln Electric IDEALARC R3R-500 User Manual
Page 8: Physical dimensions
Advertising
INSTALLATION
A-2
A-2
IDEALARC R3R
TECHNICAL SPECIFICATIONS - IDEALARC R3R-300
INPUT - THREE PHASE ONLY
Standard Voltage
Input Current @ Rated Output
230V
56A
460V
28A
RATED OUTPUT
Duty Cycle
Amps
Volts at Rated Amps
100%
230
29
60%
300
32
35%
375
35
OUTPUT
Current Range
Maximum Open Circuit Voltage
45 to 375 Amps
67 VDC
RECOMMENDED INPUT WIRE AND FUSE SIZES AT 60% DUTY CYCLE
Input Wire Size
Ground Wire Size
Input Voltage /
Fuse
Input Ampere
Type 75°C
Type 75°C
Frequency
(Super Lag)
Rating on
Copper Wire in
Copper Ground
or Breaker Size
Nameplate
Conduit
Wire in Conduit
Volts/Hz
AWG (IEC) Sizes
AWG (IEC) Sizes
230/60
80
56
8 (10 mm
2
)
8 (10 mm
2
)
460/60
40
28
10 (6 mm
2
)
10 (6 mm
2
)
PHYSICAL DIMENSIONS
Height
Width
Depth
Weight
27.50 in.
22.25 in.
33.10 in.
350 lbs.
(700 mm)
(565 mm)
(840 mm)
(159 kg)
Advertising
This manual is related to the following products: