TROUBLESHOOTING & REPAIR

F-23

F-23

IDEALARC R3R

TABLE F.1 – PHASE ANGLE WINDING VOLTAGES

From Lead #

To Lead #

Expected VAC

201

204

66 VAC

202

204

66 VAC

203

204

66 VAC

MAIN TRANSFORMER (T1) VOLTAGE TEST (continued)

FIGURE F.9 – CONTROL BOARD G2206 - [

] TEST POINTS

FIGURE F.10 – CONTROL BOARD G1575 - [

] TEST POINTS

R3R CONTROL

G2206 - [

]

R3R CONTROL

G1575 - [

]

Plug P3

#201

#202

#203

#204

201

202

203

204

Plug P4