Operation, General description – Lincoln Electric IDEALARC R3R-500 User Manual

Page 19

Advertising
background image

GENERAL DESCRIPTION

The Idealarc R3R is an SCR controlled constant cur-
rent DC output power source for welding and cutting.
The R3R-300 uses a single range potentiometer con-
trol. The R3R-400 and R3R-500 have separate low
and high range controls. The welder’s unique combi-
nation of 3 phase transformer, SCR/Diode bridge rec-
tifier, arc control choke, and solid state control system
deliver outstanding arc characteristics. For stick weld-
ing, an Arc Force Control enables the Idealarc-R3R to
create a soft welding arc for critical applications or a
forceful driving arc for heavy duty applications.

RECOMMENDED PROCESSES

The Idealarc R3R is recomended for stick and DC TIG
welding and air/carbon arc gouging.

DESIGN FEATURES AND ADVANTAGES

• Input line voltage compensation keeps output con-

stant for fluctuations of ± 10%.

• Hinged front control panel provides easy access to

printed circuit boards and other control circuitry.

• Fully enclosed fan motor with permanently lubri-

cated, sealed ball bearings needs no maintenance.

• Fully recessed control panel protects controls and

minimizes accidental contact.

• Recessed output terminals reduces chance of acci-

dental contact.

• Low profile case permits installation under a work-

bench.

• Removable rear access panel provides easy access

to input contactor and input lead connections.

• Removable case sides provide easy access for ser-

vice or inspection, even when machines are stacked.

• Dripproof enclosure design permits outdoor operation.

• Double-dipped transformer, SCR bridge, and choke

resist corrosion.

WELDING CAPABILITY

The Idealarc R3R has the following duty cycle ratings.
If the duty cycle is exceeded, a thermal protector will
shut off the machine output until it cools to normal
operating temperature. The amber thermal protection
indicator light will turn on until the machine cools.

60% Duty Cycle*

Amps

Volts

R3R-300

300

32

R3R-400

400

36

R3R-500

500

40

*Based on a 10 minute time period. For example, a 60% duty cycle
means 6 minutes on and 4 minutes off.

OPERATION

B-3

B-3

IDEALARC R3R

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Advertising
This manual is related to the following products: