TROUBLESHOOTING & REPAIR

F-63

F-63

IDEALARC R3R

RETEST AFTER REPAIR (R3R 500)

Retest a machine:

• If it is rejected under test for any reason that requires you to remove any mechanical part which could affect the

machine’s electrical characteristics. OR

• If you repair or replace any electrical components.

INPUT IDLE AMPS AND WATTS

Input Volts/Phase/Hertz

Maximum Idle Amps

Maximum Idle KW

200/3/60

10.9

1.2

208/3/60

10.5

1.2

230/3/60

9.5

1.2

415/3/60

5.3

1.2

440/3/60

5.0

1.2

460/3/60

4.8

1.2

550/3/60

4.0

1.2

575/3/60

3.8

1.2

200/3/50

19.8

1.2

220/3/50

18.0

1.2

230/3/50

17.2

1.2

380/3/50

10.4

1.2

400/3/50

9.9

1.2

415/3/50

9.5

1.2

440/3/50

9.0

1.2

500/3/50

7.9

1.2

550/3/50

7.2

1.2

OPEN CIRCUIT VOLTAGES

Test Points

Input Hertz

Open Circuit Volts

Welding Output Terminals

60

64/72VDC

Welding Output Terminals

50

61/69VDC

WELDING OUTPUT LOAD TEST

Output Control Settings

Amps

Volts

Dial Selector at “A”

60

20VDC (Maximum)

Minimum

Dial Selector at “B”

625

44 to 49 VDC

Maximum

Advertising