TROUBLESHOOTING & REPAIR

F-36

F-36

IDEALARC R3R

This is the typical DC voltage wave-
form generated from a properly oper-
ating machine. Note that each verti-
cal division represents 20 volts and
that each horizontal division repre-
sents 5 milliseconds in time. The
machine was loaded with a resis-
tance grid bank. The meter reads
500 amps at 40VDC.

Note: Scope probes connected at
machine output terminals: (+) probe
to positive terminal, (-) probe to neg-
ative terminal. (R3R 500 machine)

SCOPE SETTINGS

Volts/Div.....................20V/Div.
Horizontal Sweep.....5 ms/Div.
Coupling ............................DC
Trigger .........................Internal

TYPICAL OUTPUT VOLTAGE WAVEFORM – MACHINE LOADED

0 volts

5 ms

20 volts