CHAPTER 5: TROUBLESHOOTING

7400B Data Module

User’s Guide

Page 5-3

Symptom

Problem

Solution

Call disconnects

The speed of the far end

immediately after an

device is higher than the

attempt to connect; NO

speed of the local terminal

CARRIER may be

device.

displayed on the local
terminal device; CHECK
SPEED
LED lights.

The far end device is set
up for half-duplex or
synchronous operation.

Change the speed of the local
terminal device to match that of the
far end device. If the speed of the
far end device is not known, set the
local terminal device to the highest
speed available.

The 7400B Data Module cannot
communicate with a far end device
that is operating half-duplex or
synchronous. This problem can be
resolved only if the far end device
can be reconfigured for full-
duplex, asynchronous operation.

Call disconnects

The far end device is busy

Try the call again.

immediately after an

with another call.

attempt to connect; BUSY
may be displayed on the
local terminal device;
CHECK SPEED LED
does not light.

The telephone number

Check the number of the far end

was dialed incorrectly.

device that you wish to call and try

the call again.

The far end device is not

This situation can only be resolved

busy, but the PBX has

by having the PBX readministered

restricted access to the

to remove the access restriction.

called device.