Lucent Technologies AT&T 7400B User Manual

Page 61

Advertising
background image

APPENDIX A: AT COMMAND SET

DEFINITY Communications System

7400B Data Module

Page A-14

User’s Guide

Command:

Function:

Type:

Arguments:

S-Register:

Example:

Comments:

See Also:

&F

Load the factory-default configuration.

immediate

none

none

at&f

[ Enter ]

The factory-default configuration values are permanently stored in
ROM and can be recalled at any time. No reset or self-test is initiated
by issuing the

&F

command.

Chapter 4, “Operation and Configuration.”

Command:

&S

Function:

Data Set Ready (DSR) options.

Type:

configuration

Arguments:

The

&S

command accepts one of two arguments as follows:

0 - (or no argument) the DSR circuit is maintained on at all times
(factory-default setting)

1 - the DSR circuit operates according to the EIA-232-D standard.

S-Register:

Bit 6 of S21 is set according to the argument used with the

&S

command.

Example:

at&s1

[ Enter ]

Comments:

In the example, the DSR circuit is configured to operate according to
the EIA-232-D standard. Regardless of which option is currently in
effect, the DSR circuit of the 7400B Data Module is always off during
self-test, and turns off for 0.5 second during a disconnect sequence.

See Also:

Chapter 4, “Operation and Configuration.”