CHAPTER 5: TROUBLESHOOTING

DEFINITY Communications System

7400B Data Module

Page 5-4

User’s Guide

Symptom

Problem

Solution

The PC communications

The data module has

software indicates that the

ignored the on-to-off

call has been

transition of the DTR

disconnected, but the

lead.

DATA LED remains lit.

at&d2

[ Enter ]

The data module has

ignored the

H

(hang-up)

command.

From command mode, type the
command

to set the DTR lead option to
disconnect on DTR lead transition
from on-to-off. Alternatively,
determine and use the command
provided by the communications
software to implement this change.

Ensure that after the escape
sequence

(+++)

has been entered to

switch the data module to
command mode, an adequate pause
is allowed before issuing the

H

command. In escaping to
command mode with the result
codes enabled, the data module
must be given time to return OK or
0 before it is ready to accept a
command.