DEFINITY Communications System

CHAPTER 5: TROUBLESHOOTING

7400B Data Module

User’s Guide

Page 5-7

Symptom

Problem

Solution

Commands are displayed

The local terminal device

Set the terminal device for one of

without error as they are

is set to a speed not

the supported speeds: 300, 1200,

typed (echoed), but the

supported by the 7400B

2400, 4800, 9600, or 19200 bps.

data module does not

Data Module.

respond to any command.

The CONNECT message

The data module is

Configure the data module to send

is sent without a speed

configured to display only

CONNECT

nnnn

messages for all

indication, but the far end

the basic set of result

speeds except 300 bps by typing

device is not set at 300

codes (option

x0).

bps.

atx4

[ Enter ]

The terminal device has

A defective or non-

Replace the EIA-232-D cable with

its DTR lead turned on,

standard (null-modem)

one that is wired correctly.

but the TR LED is off.

EIA-232-D cable is in use.