DEFINITY Communications System

APPENDIX A: AT COMMAND SET

7400B Data Module

User’s Guide

Page A-13

Command:

Function:

Type:

Arguments:

S-Register:

Example:

Comments:

at&d2

[ Enter ]

See Also:

&D

Data Terminal Ready (DTR) options.

configuration

The

&D

command accepts one of four arguments as follows:

0 - ignore the DTR interchange circuit (factory-default setting).

1 - return to the command state if an on-to-off transition is detected

on the DTR input; an active data call is not disconnected.

2 - go on hook when an on-to-off transition is detected on the DTR
input (EIA-232-D standard); an active data call is disconnected.

3 - perform a reset if an on-to-off transition is detected on the DTR
input; an active data call is disconnected.

Bits 3 and 4 of S21 are set according to the option used with the

&D

command.

In the example, the DTR circuit is set according to the EIA-232-D
standard. This would be an appropriate setting for when the 7400B
Data Module is used at a remote site as a dedicated device to

automatically answer an incoming data call.

For the 0 option, the front panel DTR indicator (TR LED) is always on,
regardless of the state of the DTR input; for all other options the
indicator follows the state of the DTR input.

If the change of state for the DTR circuit persists for a time shorter
than specified in S25, the change is ignored.

Chapter 4, “Operation and Configuration”, Appendix B, “S-
Registers.”