Lucent Technologies AT&T 7400B User Manual

Page 75

Advertising
background image

APPENDIX B: S-REGISTERS

DEFINITY Communications System

7400B Data Module

Page B-10

User’s Guide

Register:

S16

Description:

This S-register stores test function status in a bit-mapped format as

follows:

bit 0 — local digital loop test; 0 = test disabled, 1 = test in progress

(default = 0, see the

&T1

and

&T2

commands)

bit 1 — not used (always set to 0)

bit 2 — local data loop test; 0 = disabled, 1 = test in progress

(default = 0, see

&T3

command)

bit 3 — status bit for remote digital loop initiated by remote system;
0 = off, 1 = in progress (default = 0, see

&T4

and

&T5

commands)

bit 4 — remote digital loop; 0 = disabled, 1 = in progress (default = 0,
see

&T6

command)

bit 5 — remote digital loop with self-test 0 = disabled, 1 = in
progress (default = 0, see

&T7

command)

bit 6 — local digital loop with self-test; 0 = disabled, 1 = in progress

(default = 0, see

&T8

command)

bit 7 — not used (always set to 0)

Range of

Values:

Storable:

Comments:

Value may be 00 to FF hexadecimal; factory-default settings produce a
value of 00 (see comment 1).

no

1 .

Only one of the tests may be in progress at any time. The

T0

command terminates any locally initiated test in progress and

sets S-register 16 to 00.

Refer to the explanation of hexadecimal values under the Range

of Values label description at the beginning of this appendix.

2 .

See Also:

Chapter 4, “Operation and Configuration”; refer to the indicated AT
command in Appendix A, “AT Command Set.”

Register:

S17

— not used