Page A-9

Command:

Function:

Type:

Arguments:

S-Register:

Example:

Comments:

atq1

[ Enter ]

See Also:

Q

Turn the display of result codes on or off.

configuration

No argument or an argument of 0 enables the display of result codes;
an argument of 1 disables the display of result codes. The factory-
default is result codes enabled.

Bit 2 of S14 is set according to the argument used with the

Q

command.

In the example, the result codes are disabled. Use this option only if
you wish to prevent the data module from returning result codes after
an AT command is issued.

Chapter 4, “Operation and Configuration;” result codes in either
Chapter 4 or Appendix D, “Summary Tables;” the

V

and

X

commands in this appendix.

Command:

V

Function:

Select format for result codes.

Type:

configuration

Arguments:

No argument or an argument of 0 causes the data module to return the
short form or numeric result codes; an argument of 1 causes the data
module to return the verbose form or text message result codes. The
factory-default setting is the verbose form.

S-Register:

Bit 3 of S14 is set according to the argument used with the

V

command.

Example:

atv

[ Enter ]

Comments:

The example would set the short form or numeric result code format.

See Also:

Chapter 4, “Operation and Configuration”; result codes in either
Chapter 4 or Appendix D, “Summary Tables;” the

Q

and

X

commands in this appendix.

Advertising