APPENDIX B: S-REGISTERS

DEFINITY Communications System

7400B Data Module

Page B-14

User’s Guide

Register:

S23

Description:

This S-register is used to store the status of bit-mapped options as

follows:

bit 0 — allow remote loop request from remote system; 0 = disabled,

1 = enabled (default = 1, see

&T

command)

bits 1, 2, and 3 — local communications speed (see comment 1)

0 = 300 bps

1 = not used

2 = 1200 bps
3 = 2400 bps (factory-set default)
4 = 4800 bps

5 = 9600 bps

6 = 19200 bps

7 = not used

bits 4 and 5 — local parity setting; 0 = even, 1 = space, 2 = odd, and
3 = mark/none (default = 0)

bit 6 and 7 — not used (see comment 2)

Range of

Values:

Storable:

Comments:

Value may be 00 to FF hexadecimal; factory-default settings produce a
value of 07 hexadecimal (see comment 3).

yes

1.

Hayes compatible modems use only bits 0, 1 and 2 for speeds up
to 2400 bps. The 7400B Data Module uses bit 3 to support
speeds above 2400 bps.

2 .

Bits 6 and 7 are set by the appropriate command, but there will
be no other effect.

3 .

Refer to the explanation of hexadecimal values under the Range

of Values label description at the beginning of this appendix.

See Also:

Chapter 4, “Operation and Configuration”; refer to the indicated AT
command in Appendix A, “AT Command Set.”