LN-7 Connection Instructions
An LN-7 can only be used with the “Factory” &

Advanced Process

versions of the 350-Pro.

• Turn the Invertec power switch "off".
• Connect the K480 control cable from the LN-7 to the

14-pin MS-style connector.

• Connect the electrode cable to the output terminal of the

polarity required by electrode. Connect the work lead to
the other terminal.

Set the meter polarity switch on the front of the Invertec

to coincide with wire feeder polarity used. The wire
feeder will now display the welding voltage.

• If K480 is not available, see connection diagram

S19404 for modification of K291 or K404 LN-7 input
cable with K867 Universal Adapter Plug.

If a remote control such as K857 is to be used with the

LN-7, the remote can be connected directly to the 6-pin
MS-style connector on the front of the Invertec or use a
K864 adapter to connect the LN-7 and the remote to the
14-pin MS-style connector. (See connection diagram
S19901)

LN-10 Connection Instructions
An LN-10 can only be used with the “Factory” &

Advanced Process

versions of the 350-Pro.

• Turn the Invertec power switch "off"
• Connect the K1505 control cable from the LN-10 to the

14-pin MS-style connector.

• Connect the electrode cable to the output terminal of

polarity required by the electrode. Connect the work lead
to the other terminal.

• Set the meter polarity switch on the front of the Invertec

to coincide with wire feeder polarity used.

• See the LN-10 manual for details on accessing Control

DIP Switch

LN-742 Connection Instructions

An LN-742 can only be used with the “Factory” &

Advanced Process

versions of the 350-Pro.

• Turn the Invertec power switch "off"
• Either a K591 or a K593 Input cable assembly is

required to connect the LN-742 to the Invertec.

• Connect the control cable from the LN-742 to the

14-pin MS-style connector.

• Connect the electrode cable to the output terminal

of the polarity required by electrode. Connect the
work lead to the other terminal.

• Set the meter polarity switch on the front of the

Invertec to coincide with wire feeder polarity used.
The wire feeder will now display the welding volt-
age.

• If a remote control such as K857 is to be used with the

LN-742, the remote can be connected directly to the 6-pin
MS-style connector on the front of the Invertec or use a
K864 adapter to connect the LN-742 and the remote to
the 14-pin MS-style connector.

Cobramatic Connection Instructions

A Cobramatic can only be used with the “Factory” &

Advanced Process

versions of the 350-Pro.

• Turn the Invertec power switch "off"
• Connect the control cable from the Cobramatic to

the 14-pin MS-style connector.

• Connect the electrode cable to the output terminal

of the polarity required by electrode. Connect the
work lead to the other terminal.

• Set the meter polarity switch on the front of the

Invertec to coincide with wire feeder polarity used.

• If a remote control such as K857 is to be used with

the Cobramatic, the remote can be connected
directly to the 6-pin MS-style connector on the front
of the Invertec or use a K864 adapter to connect
the cobramatic and the remote to the 14-pin MS-
style connector.

TIG Module K930-2
The TIG Module connects to the Factory and Advanced
Process V350-Pro versions with a K936-1 (9-14 pin)
control cable. Connect the K936-1 to the MS-style
connector.

The TIG Module can also be used with the V350-Pro
Construction version. A K936-4 control cable is
required to supply 115VAC to the TIG Module from an
external 115VAC supply.

General Instructions for Connection of Wire
Feeders to V350-Pro
Wire feeders other than those listed above may be
used provided that the auxiliary power supply rating of
the V350-Pro is not exceeded. K867 universal adapter
plug is required. See connection diagram S24985 on
page F-4.

REMOTE CONTROL OF INVERTEC
Remote Control K857, Hand Amptrol K963 and Foot
Amptrol K870.

UNDERCARRIAGE MOUNTINGS

5.50

10.00

MOUNTING HOLE LOCATIONS