Tests detailed in table f.2, Troubleshooting & repair, Test point terminals analog meter x10 range – Lincoln Electric INVERTEC SVM158-A User Manual

Page 73: Input rectifier test (continued)

Advertising
background image

TROUBLESHOOTING & REPAIR

F-23

F-23

V350-PRO

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

9.

If the input rectifier does not meet the
acceptable readings outlined in Table F.2
the component may be faulty. Replace

Note: Before replacing the input rectifier,
check the input power switch and per-
form the Main Switch Board Test. Also
check for leaky or faulty filter capacitors.

10. If the input rectifier is good, be sure to

reconnect leads 207, 207A, and 209 to
the correct terminals and torque to 31
inch lbs. Apply silicone sealant.

11. If the input rectifier is faulty, see the

Input Rectifier Bridge Removal &
Replacement
procedure.

12. Replace the case wraparound cover.

INPUT RECTIFIER TEST (CONTINUED)

Table F.2 Input Rectifier Test Points

TEST POINT TERMINALS

ANALOG METER

X10 RANGE

A
B

C

A
B

C

A
B

C

207
207
207

207A
207A
207A

209
209
209

207
207
207

207A
207A
207A

209
209
209

A
B

C

A
B

C

A
B

C

Greater than 1000 ohms
Greater than 1000 ohms
Greater than 1000 ohms

Greater than 1000 ohms
Greater than 1000 ohms
Greater than 1000 ohms

Less than 100 ohms
Less than 100 ohms
Less than 100 ohms

Less than 100 ohms
Less than 100 ohms
Less than 100 ohms

Less than 100 ohms
Less than 100 ohms
Less than 100 ohms

Greater than 1000 ohms
Greater than 1000 ohms
Greater than 1000 ohms

+ PROBE

- PROBE

Acceptable Meter Readings

Advertising