TROUBLESHOOTING & REPAIR

AUXILIARY TRANSFORMER NO.1 TEST (continued)

F-35

F-35

V350-PRO

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

7.

Carefully apply the correct input voltage to the
V350-PRO and check for the correct sec-
ondary voltages per table F.4. Make sure the
reconnect jumper lead and switch are config-
ured correctly for the input voltage being
applied. Make sure circuit breaker (CB3) is
functioning properly.

NOTE: The secondary voltages will vary if the
input line voltage varies.

8.

If the correct secondary voltages are present,
the auxiliary transformer is functioning proper-
ly. If any of the secondary voltages are miss-
ing or low, check to make certain the primary
is configured correctly for the input voltage
applied. See Wiring Diagram.

High voltage is present at primary of

Auxiliary Transformer.

9.

If the correct input voltage is applied to the
primary, and the secondary voltage(s) are not
correct, the auxiliary transformer may be
faulty.

10. Remove the input power to the V350-PRO.

11. Install the case wraparound cover using a

5/16” nut driver.

TABLE F.4

WARNING

LEAD IDENTIFICATION

NORMAL EXPECTED VOLTAGE

31 TO 532

115 VAC

42 TO 541

24 TO 541

42 VAC

24 VAC

28 VAC

54 TO 541