ACCESSORIES

CONNECTION OF THE LN-742 TO THE
V350-PRO (SEE FIGURE C.7)

NOTE: AN LN-7 CAN ONLY BE USED WITH A FAC-
TORY OR “CE” VERSION OF THE V350-PRO.

1. Remove input power to the V350-PRO.

2. Connect the electrode cable from the LN-742 to

the “+” terminal of the welder. Connect the work
cable to the “-” terminal of the welder.

NOTE: Figure C.7 shows the electrode connected
for positive polarity. To change polarity, shut the
welder off and reverse the electrode and work
cables at the output terminals.

NOTE: Welding cable must be sized for current
and duty cycle of application.

3. Connect the K591 control cable to the 24/42VAC

14 pin amphenol on the back of the V350-PRO
and the input cable plug on the LN-742.

4. Set the “VOLTMETER” switch to “+” or “-”

depending on the polarity chosen.

5. Set the “MODE” to the “CV-WIRE” position..

6. Set “CONTROL SELECT” to “LOCAL”.

7. Place the “WELD TERMINALS SELECT” in the

“REMOTE” position.

8. Adjust wire feed speed at the LN-742.

9. Set the “ARC” control at “0” initially and adjust to

suit.

+ -

14 PIN

AMPHENOL

TO LN-742 INPUT

CABLE PLUG

TO WORK

K591 CONTROL CABLE

ELECTRODE CABLE

TO WIRE FEED UNIT

(24/42VAC)

AT REAR OF

MACHINE

Figure C.7 V350-PRO/LN-742 Connection Diagram