TROUBLESHOOTING AND REPAIR

RETEST AFTER REPAIR

F-94

F-94

V350-PRO

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Required Action

Expected Results

Rt. display

Lft.display

Test

Steps

23

24

25

26

27

28

29

30

31

32

Verify that the Advanced Process Panel upper right dis-
play contains the following pattern and that the bright-
ness of the characters is uniform:

“0123456789ABCDEF”

Press and release the Advanced Process Panel
Memory button to advance to the next step.

Verify that the Advanced Process Panel lower right dis-
play contains the following pattern and that the bright-
ness of the characters is uniform:

“0123456789ABCDEF”

Press and release the Advanced Process Panel
Memory button to advance to the next step.

The weld terminals “ON” and “REMOTE” LEDs should
both be off. Press the weld terminals push button to
select weld terminals (studs) “ON” and verify that the
weld terminals “ON” LED turns on.

Press the weld terminals push button again to select
weld terminals “REMOTE” and verify that the weld ter-
minals “ON” LED turns off and that the weld terminals
“REMOTE” LED turns on.

Press the weld terminals push button again and verify
that both of the weld terminals LEDs are off.
The “LOCAL” and “REMOTE” workpoint source LEDs
should both be off. Press the workpoint source push
button to select “LOCAL” and verify that the workpoint
source “LOCAL” LED turns on and that the “REMOTE”
workpoint source LED remains off.

Press the workpoint source pushbutton again to select
workpoint source “REMOTE” and verify that the work-
point source “LOCAL” LED turns off and the workpoint
source “REMOTE” workpoint source LED turns on.

Press the workpoint source pushbutton again and verify
that both workpoint source LEDs are off.

This will only appear if a potentiometer is already con-
nected to the 6-pin amphenol connector on the front of
the machine. If this message appears, disconnect the
potentiometer from the 6-pin amphenol connector.

Connect a remote output control potentiometer to the 6-
pin amphenol connector on the front of the machine.

dISP

dISP

SudS

SudS

SudS

LorE

LorE

LorE

dcon

con

3

4

on

rE

cLr

LocL

rE

cLr

6-PIn roCP

6-PIn roCP