background image

CONNECTION OF THE LN-25 TO THE
V350-PRO “ACROSS THE ARC” WITH
OPTIONAL 6 PIN K857 REMOTE CON-
TROL.

1. Remove input power to the V350-PRO.

2. Connect the electrode cable to the output terminal

of polarity required by the electrode. Connect the
work lead to the other terminal. Welding cable
must be sized for current and duty cycle of the
application.

3. Connect the K857 remote control to the 6-pin

amphenol on the V350-PRO.

4. Attach the single lead from the LN-25 control box

to the work using the spring clip on the end of the
lead. This is only a control lead - it carries no
welding current.

5. Set the voltmeter switch to the electrode polarity

chosen.

6. Set “CONTROL SELECT” to “REMOTE”.

7. Set the “MODE” to the “CV-WIRE” position.

8. Set “WELD TERMINALS SELECT” to the “ON”

position.

If you are using an LN-25 without an internal con-
tactor, the electrode will be “HOT” when the V350-
PRO is energized.

9. Set the “ARC CONTROL” to the “O” position and

then adjust to suit.

ACCESSORIES

C-5

C-5

V350-PRO

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

CAUTION

NOTE: Illustration shows electrode connected for negative polarity.

Figure C.2 V350-PRO/LN-25 ACROSS THE ARC CONNECTION DIAGRAM WITH K857

REMOTE CONTROL

+ -

6 pin
Amphenol

To Work

Electrode Cable

LN-25
Wire Feeder

Work Clip Lead

To Work

K857
Remote Control