OPERATION

B-5

B-5

V350-PRO

7A. ADVANCED PROCESS PANEL

(See Figure B.2)

To program Welding modes. SELECT knob is used to
Scroll through all Welding modes. The MEMORY but-
ton is used to store and access Welding modes into
locations M1 thru M8.

Modes:
In addition to the 5 welding modes described in SEC-
TION 7,
the Advanced Process Panel allows you to
select the Following additional modes.

Power Mode

In the Power Mode;

The work point will be in the Volts window. The Amp
window will have CP displayed indicating Constant
Power. Once current starts flowing and during the 5
second “Hold” feature the displays will show Volts
and Amps respectively. Refer to the detailed expla-
nation at the end of this section.

Gouge

Air Carbon Arc Cutting (CAC-A) is a physical means
of removing base metal or weld metal by using a car-
bon electrode, an electric arc and compressed air.

Pulsed Modes

In Pulse Modes;

The work point will be in the Amps window and
should be set close to the wire feed speed of the
wire feeder in inches per minute. The Volts window
will have SPd displayed indicating Wire Feed
Speed. Once current starts flowing and during the 5
second “Hold” feature the displays will show amps
and volts.

Pulse Mode features that are displayed while select-
ing a Welding pulse mode are listed below;
Steel - .030, .035, .045, .052 – Argon Blends
Stainless Steel - .030, .035, .045 – Argon Blends &
Helium/Argon Blends

Aluminum - .035, 3/64, 1/16 – 4043 & 5356

Metal Core - .045, .052 – Argon Blends
Nickel - .035, .045 – Argon/Helium blends

Refer to the detailed explanation at the end of this
section.

MEMORY

MEMOR

MEMORY BUTTON
(M1

(M1 THRU M8)

OUTPUT KNOB

SELECT BUTTON

ON

(HOT START OR ARC CONTROL)

ADJUST KNOB

ADJUST KNOB
(0 THRU 10-HOT START)
(-10 THRU 0 AND
0 THRU +10-ARC CONTROL)

SELECT KNOB
(SCOLLS WELDING PR

WELDING PROCESSES)

SELECT

ADJUST

SELECT

7A

REMO

REMOTE

TE

ON

ON

REMO

REMOTE

TE

LOCAL

LOCAL

WELD TERMINALS

OUTPUT

CONTROL

SELECT

SELECT

MPS

A

OLTS

V

FIGURE B.2

ADVANCED PROCESS PANEL VERSION