Fault code explanations, See the fault code, Explanations – Lincoln Electric INVERTEC SVM158-A User Manual

Page 59: See fault code explanations, Troubleshooting & repair

Advertising
background image

SERVICE FACILITY

CORRECTIVE

ACTION

CORRECTIVE

ACTION

DESCRIPTION/

DEFINITION

31

32

Main transformer
primary over current

Capacitor bank “A”
(lower) is under
voltage

Turn the machine off and
back on to reset the
machine. If condition
persists, contact an
authorized Lincoln Field
Service Facility.

Make sure the reconnect
switches are configured
for the input voltage
being applied to the
machine. The machine
is self clearing when
condition ceases.

Perform the Main Switch
Board Test.

Perform the Power
Board Test.

There may be a problem
with the primary current
sensors (CT) located on
the main switch board.
See the Wiring diagram

The control board may
be faulty.

There may be a problem
with the V/F signals from
the main switch board to
the control board.

Perform the Main Switch
Board Test.

Perform the Power
Board Test.

The control board may
be faulty.

TROUBLESHOOTING & REPAIR

F-9

F-9

V350-PRO

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

FAULT CODES

NOTE:

If more than one fault message is being displayed, perform all the checks for the faults

before replacing the printed circuit board