21. Replace the current transducer.

22. Replace the two 3/8” mounting nuts previously

removed.

23. Reconnect plug #J90 to the current transducer.

24. Replace any necessary cable ties previously cut.

25. From the rear of the machine, replace the heavy

flex lead to the bottom of the output diode
heatsink assembly using a 1/2” wrench. Note:
Don’t forget to include all washers.

26. Replace the output diode heatsink assembly pre-

viously removed using a 3/8” wrench.

Note: Be sure to place insulation in its original

location.

27. Replace leads X2, #20, X4, # 40 previously

removed from the two output diode modules.
Torque to 30-40 inch lbs.

28. Perform the Snubber Board Replacement

Procedure.

29. The rear of the machine may now be placed back

into its original position.

30. Using a 3/8” wrench, replace leads #202, #203,

#206, and #207A previously removed from the
reconnect switches.

31. Tighten the metal nut previously removed from the

inside of the rear wall on the back of the machine.
Channel locks may be necessary.

32. Replace the large plastic nut from around input

power line located at the back of the machine.

33. Replace the five leads to the reconnect panel in

their proper locations.

34. Replace the two CB2 circuit breaker leads previ-

ously removed.

35. Using a 5/16” nut driver, replace the four screws

at the bottom and right side of the rear assembly.

36. Replace the case wraparound cover.

37. Perform the Voltage and Current Calibration

Procedure.

TROUBLESHOOTING & REPAIR

CURRENT TRANSDUCER REMOVAL AND REPLACEMENT (continued)

F-91

F-91

V350-PRO

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Advertising