Installation, Technical specifications – Lincoln Electric INVERTEC SVM158-A User Manual
Page 8
V350-PRO
A-2
INSTALLATION
A-2
TECHNICAL SPECIFICATIONS -
INVERTEC V350-PRO
INPUT AC VOLTAGE & DC OUTPUT
Product
Ordering
Input AC
Rated DC Output
Output
Weight
Dimensions
Open
Name Information
Voltage
Amps/Volt
Range
with Cord
HxWxD
Circuit
/Duty Cycle
(continuous)
Voltage
K1728-5
Construction
Construction
(81.0 lbs.)
200
350A / 34V / 60%
(36.7 kg.)
14.8” x 13.3” x
Invertec
K1728-6
208-230/
27.8”*
V350-
Factory
380-400/
AMPS
Factory
(373 x 338 x
PRO
415-460/
5-425
(81.0 lbs.)
706*)mm
60/50 Hz
K1728-7
575
300A / 32V /100%
(36.7 kg.)
80 VDC
Advanced 1& 3 Phase
Process
60/50 Hz
Advanced Process
(81.5 lbs.)
(37.0 kg.)
* Overall Length Including Handle, 27.8” (706mm)
Voltage
200
208
230
380
400
415
460
575
200
208
230
380
400
415
460
575
Phases
1
1
1
1
1
1
1
1
3
3
3
3
3
3
3
3
300Amps @
32Volts(100%)
Not
Recommended
76
69
Not
Recommended
Not
Recommended
41
36
31
41
39
36
23
22
22
19
16
350Amps @
34Volts(60%)
Not
Recommended
94
85
Not
Recommended
Not
Recommended
64
42
37
50
50
42
28
27
26
23
18
Line Cord
AWG
2
4
---
6
8
8
8
6
8
8
8
8
8
8
Fuse size
---
125A
125A
---
---
80A
70A
50A
80A
80A
70A
50A
50A
50A
50A
35A
V350-PRO INPUT CURRENT
OUTPUT CABLES, CONNECTIONS AND LIMITATIONS
Recommemded Fuse Sizes Base On The U.S. National Electrical Code And Maximum Machine Outputs
Input 50/60 Hz
Output
Recommended
Note 1. Not rated is indicated by 4-x’s in the box on the rating plate.
Note 2. When operating on these inputs, the line cord should be changed to an input conductor of 6 AWG or larger.
Select The output cable size based upon the following chart.
Cable sizes for Combined Length of Electrode and Work Cable (Copper) 75C rated:
DUTY CYCLE
100%
60%
CURRENT
300
350
LENGTH UP TO 200FT.(61m)
1/0
1/0
200-250 FT. (61-76m)
1/0
2/0
Notes
Note 1
Note 2
Note 2
Note 1
Note 1
Note 2
Note 2
Note 2