Accessories, Connection of lincoln elec- tric wire feeders, Caution – Lincoln Electric INVERTEC SVM158-A User Manual

Page 30

Advertising
background image

CONNECTION OF LINCOLN ELEC-
TRIC WIRE FEEDERS

CONNECTION OF THE LN-25 TO THE
V350-PRO “ACROSS THE ARC” WITH
OPTIONAL 6 PIN K441-1 REMOTE CON-
TROL.

1. Remove input power to the V350-PRO.

2. Connect the electrode cable to the output terminal

of polarity required by the electrode. Connect the
work lead to the other terminal. Welding cable
must be sized for current and duty cycle of the
application.

3. Attach the single lead from the LN-25 control box

to the work using the spring clip on the end of the
lead. This is only a control lead - it carries no
welding current.

4. Set the voltmeter switch to the electrode polarity

chosen.

5. Set “CONTROL SELECT” to “REMOTE”.

6. Set the “MODE” to the “CV-WIRE” position.

7. Set “WELD TERMINALS SELECT” to the “ON”

position.

If you are using an LN-25 without an internal con-
tactor, the electrode will be “HOT” when the V350-
PRO is energized.

8. Set the “ARC CONTROL” to the “O” position and

then adjust to suit.

CAUTION

ACCESSORIES

C-4

C-4

V350-PRO

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

+ -

6 pin
Amphenol

To Work

Electrode Cable

Optional K444-1
Remote Control

LN-25
Wire Feeder

Work Clip Lead

To Work

Figure C.1 V350-PRO/LN-25 ACROSS THE ARC CONNECTION DIAGRAM

NOTE: Illustration shows electrode connected for negative polarity.