TROUBLESHOOTING AND REPAIR

1

2

5

6

#550

#551

J83

#551(-)

BLACK

#550(+)

WHITE

DRIVE MOTOR TEST

(continued)

FIGURE F.3 – DRIVE MOTOR TEST

PROCEDURE

1. Remove input power to wire feed

unit.

2. Using the 3/8 in. nut driver, remove

the cover from the wire feeder.

3. Locate the two quick connectors in

the two motor armature leads. Refer
to Figure F.3.

Do NOT disconnect

the leads.

4. Apply the correct input power (from

the Power Wave 455 control cable) to
the wire feede. Activate the gun
trigger and with the motor running
check at the quick connectors [#550
White (+) to #551 / Black (-)] for
approximately 1 VDC to 32 VDC
dependent upon motor speed. The
motor speed should vary with
changes in motor armature voltage.

5. If the correct voltages are NOT

present at the motor leads, check the
associated leads between the motor
and plug J83 on the feedhead board.
If the leads are OK, the feedhead
board may be faulty.

6. If the correct voltages are present at

motor armature leads and the motor
does not run and vary speed with
changes in armature voltage, the
motor or gear box may be faulty.
See Gear Box and Drive Motor
Removal and Replacement
.

7. Install the wire feeder cover using the

3/8 in. nut driver.